01 13 282043Z APR 98 PP PP UUUU AA ZYUW FROM CDRAMCOM REDSTONE ARSENAL AL//AMSAM-SF-A// TO AIG 8881 TEXT UNCLAS SUBJECT - AVIATION SAFETY ACTION MESSAGE, MAINTENANCE MANDATORY, RCS CSGLD-1860(R1), ALL CH-47D AND MH-47E AIRCRAFT, MANDATORY TORQUE CHECK AND REPLACEMENT OF AUXILIARY POWER UNIT BOLTS, (CH-47-98-ASAM-03), (TB 1-2835-205-20-3). NOTE THIS IS AN AVIATION SAFETY ACTION MESSAGE ISSUED IAW AR 95-1, CHAPTER 6,1 SEP 97. THIS MESSAGE HAS NOT BEEN TRANSMITTED TO UNITS SUBORDINATE TO ADDRESSEES. ADDRESSEES SHOULD IMMEDIATELY RETRANSMIT THIS MESSAGE TO ALL SUBORDINATE UNITS, ACTIVITIES OR ELEMENTS CONCERNED. THE RETRANSMITTAL SHALL REFERENCE THE MESSAGE. ACTION ADDRESSES WILL IMMEDIATELY VERIFY THIS TRANSMISSION TO CDR, AMCOM, ATTN: AMSAM- SF-A (SOF COMPLIANCE OFFICER). 1. PRIORITY CLASSIFICATION - A. AIRCRAFT IN USE - UPON RECEIPT OF THIS MESSAGE THE CONDITION STATUS SYMBOL OF THE CITED AIRCRAFT WILL BE CHANGED TO A RED HORIZONTAL DASH //-//. THE RED HORIZONTAL DASH //-// MAY BE CLEARED WHEN THE INSPECTION OF PARA 8 BELOW IS COMPLETED. THE AFFECTED AIRCRAFT SHALL BE INSPECTED AS SOON AS PRACTICAL BUT NO LATER THAN THE TASK/INSPECTION SUSPENSE DATE. FAILURE TO COMPLY WITH THE REQUIREMENTS OF THIS MESSAGE WITHIN THE TIME FRAME WILL CAUSE THE STATUS SYMBOL TO BE UPGRADED TO A RED //X//. B. AIRCRAFT IN DEPOT MAINTENANCE - AIRCRAFT WILL NOT BE ISSUED UNTIL COMPLIANCE WITH THIS ASAM HAS BEEN COMPLETED. C. AIRCRAFT UNDERGOING MAINTENANCE - SAME AS PARA 1A. D. AIRCRAFT IN TRANSIT - SAME AS PARA 1A. E. MAINTENANCE TRAINERS (CATEGORY A AND B)- SAME AS PARA 1A. F. COMPONENT/PARTS IN STOCK AT ALL LEVELS (DEPOT AND OTHERS) INCLUDING WAR RESERVES - INSPECT PRIOR TO ISSUE. G. COMPONENTS/PARTS IN WORK (DEPOT LEVEL AND OTHERS) - ITEMS LISTED IN PARAGRAPHS 6 AND 7 IN WORK WILL NOT BE ISSUED UNTIL COMPLIANCE WITH THIS MESSAGE. 2. TASK/INSPECTION SUSPENSE DATE - WITHIN NEXT 10 FLIGHT HOURS/ 14 DAYS. 3. REPORTING COMPLIANCE SUSPENSE DATE - NO LATER THAN 27 MAY 1998 PER PARA 14A OF THIS MESSAGE. 4. SUMMARY OF PROBLEM - A. IN TWO SEPARATE INCIDENTS SINCE OCTOBER 1997, ONE BOLT OF SIX WHICH SECURE THE APU TURBINE ASSEMBLY TO THE REDUCTION DRIVE ASSEMBLY HAS BACKED OUT AND BEEN INGESTED INTO THE APU COMPRESSOR CAUSING FOD DAMAGE BUT NO UNCONTAINED FAILURES. THE ORIGINAL DEPOT MAINTENANCE WORK REQUEST (DMWR) AND TECH MANUALS SPECIFIED A SELF-LOCKING BOLT (P/N M4DS428-22C, NSN 5306-00-9867200). HOWEVER, THE CURRENT DMWR AND TM SPECIFY A NEW BOLT (P/N AN101118, NSN 5306-00-638-5332) WHICH IS ALSO LISTED AS SELFLOCKING BUT, IN REALITY, IS NOT. ANY T-62T-2B APU WHICH HAS BEEN SUBJECT TO A SPECIAL REPAIR ACTIVITY (SRA) SINCE 1 JAN 92 IS SUSPECT FOR HAVING THESE NON-SELF-LOCKING BOLTS. (NOTE: CHERRY POINT HAS NEVER USED THESE BOLTS.) TO PREVENT FURTHER INCIDENTS, THE DMWR AND TM WILL BE CORRECTED TO SPECIFY A BOLT WHICH IS TRULY SELF-LOCKING. ALSO, BECAUSE IT IS DIFFICULT TO IDENTIFY THE SUSPECT BOLTS BASED ONLY ON HEAD MARKINGS, ALL SIX OF THESE BOLTS IN EACH SUSPECT T-62T-2B APU NEED TO BE REPLACED, ONE AT A TIME. THE NEW BOLT (P/N NK4-13, NSN 5306-00-117-9897) IS CURRENTLY USED BY THE NAVY AND IS PROVISIONED FOR ARMY USE. ALSO, A LIMITED NUMBER OF THE ORIGINAL SELF-LOCKING BOLTS WILL BE AVAILABLE FROM DLA. UNTIL REPLACEMENT BOLTS ARRIVE, EACH BOLT WILL BE TORQUE CHECKED, TORQUE-STRIPED, AND REINSPECTED EVERY 50 FLIGHT HOURS TO ENSURE PROPER TORQUE (50 TO 70 POUND-INCHES TORQUE). B. FOR MANPOWER/DOWNTIME AND FUNDING IMPACTS SEE PARA 12. C. THE PURPOSE OF THIS MESSAGE IS TO REQUIRE TORQUE CHECKS, TORQUE-STRIPES, AND 50-HOUR INSPECTIONS OF THE BOLTS WHICH SECURE THE T-62T-2B APU TURBINE ASSEMBLY TO THE REDUCTION DRIVE ASSEMBLY TO ENSURE PROPER TORQUE UNTIL REPLACEMENT OF ALL SIX BOLTS HAS BEEN ACCOMPLISHED. 5. END ITEMS TO BE INSPECTED - ALL CH-47D AND MH-47E AIRCRAFT WITH A T-62T-2B APUS THAT HAS BEEN SUBJECT TO AN SRA SINCE 1 JAN 92. UNITS SHOULD EXAMINE MAINTENANCE RECORDS (DA FORM 2408-5-1 AND 2408-16) TO DETERMINE IF AN AIRCRAFT HAS BEEN SUBJECT OF AN SRA. IF THIS CAN NOT BE DETERMINED, THE BOLTS ARE SUSPECT AND REQUIRE REPLACEMENT. NOTE APU'S RECEIVED FROM DEPOT ACCOUNTS DIRECT FROM CHERRY POINT WILL NOT REQUIRE INSPECTION. APU'S IN ASL/PLLS WILL REQUIRE COMPLIANCE WITH THIS ASAM. 6. ASSEMBLY COMPONENTS TO BE INSPECTED - NOMENCLATURE PART NO. NSN AUXILIARY POWER UNIT T-62T-2B 2835-01-092-2037 7. PARTS TO BE INSPECTED - NOMENCLATURE PART NO. NSN BOLT, SELF-LOCKING AN101118 5306-00-638-5332 8. INSPECTION PROCEDURES - A. DETERMINE IF BOLTS ARE SUSPECT. SEE PARA 5. IF NOT SUSPECT, INSPECTION IS COMPLETE. B. IF BOLTS ARE SUSPECT: (1) PREPARE THE AIRCRAFT FOR SAFE GROUND MAINTENANCE. (2) GAIN ACCESS TO APU AIR SCREEN ASSEMBLY LOCATED BETWEEN THE TURBINE ASSEMBLY AND THE REDUCTION DRIVE ASSEMBLY. (3) CUT LOCKWIRE LACING FROM AIR SCREEN ASSEMBLY, SPREAD SCREEN ENDS, AND SEPARATE AIR SCREEN ASSEMBLY FROM TURBINE. (4) LOCATE SIX BOLTS PREVIOUSLY CONCEALED BY AIR SCREEN ASSEMBLY (REFER TO FIGURE 1, ITEM 8 OF TM 55-2835-205-23P; BOLT HEADS WILL BE TOWARD TURBINE ASSEMBLY). (5) PERFORM TORQUE CHECK TO VERIFY 50 TO 70 POUND-INCHES TORQUE FOR EACH BOLT. TORQUE BOLTS AS NECESSARY. (6). APPLY TORQUE-STRIPE ACROSS EACH BOLT HEAD. (7). REPOSITION AND SECURE AIR SCREEN ASSEMBLY. (8). VISUALLY INSPECT TORQUE-STRIPE ON EACH BOLT EVERY 50 FLIGHT HOURS AND RETORQUE BOLTS IF NECESSARY UNTIL REPLACEMENT SELF-LOCKING BOLTS ARE AVAILABLE. 9. CORRECTION PROCEDURES - A. REQUISITION SIX REPLACEMENT SELF-LOCKING BOLTS (P/N NK4-13, NSN 5306-00-117-9897) PER APU THROUGH NORMAL SUPPLY CHANNELS. B. REMOVE THE AIR SCREEN ASSEMBLY TO GAIN ACCESS TO THE BOLTS. CAUTION IN THE FOLLOWING STEP, REMOVE AND REPLACE ONLY ONE BOLT AT A TIME. THE REPLACEMENT, SELF-LOCKING BOLTS ARE ONE-TIME USE ONLY. C. REPLACE THE EXISTING BOLTS ONE AT A TIME WITH THE NEW, SELF-LOCKING NK4-13 BOLTS AND TORQUE PROPERLY (50 TO 70 POUND INCHES TORQUE). D. REPOSITION AND SECURE AIR SCREEN ASSEMBLY. E. REMOVE FROM STOCK ALL BOLTS WITH P/N AN101118, NSN 530600-638-5332. F. ADD PEN AND INK CHANGE TO TM 55-2835-205-23P, FIGURE 1, ITEM 8, CHANGING P/N AN101118, NSN5306-00-117-9897 TO P/N NK4-13, NSN 5306-00-117-9897. 10. SUPPLY/PARTS AND DISPOSITION - A. PARTS REQUIRED - SIX REPLACEMENT BOLTS (P/N NK4-13, NSN 5306-00-117-9897) PER APU. B. REQUISITIONING INSTRUCTIONS - REQUISITION REPLACEMENT PARTS USING NORMAL SUPPLY PROCEDURES. ALL REQUISITIONS SHALL USE PROJECT CODE (CC 57-59) "XDX"(X-RAY, DELTA,X-RAY). NOTE PROJECT CODE "XDX" IS REQUIRED TO TRACK AND ESTABLISH A DATA BASE OF STOCK FUND EXPENDITURES INCURRED BY THE FIELD AS A RESULT OF SOF ACTIONS. C. BULK AND CONSUMABLE MATERIALS - N/A. D. DISPOSITION - DISPOSE OF REMOVED PARTS/COMPONENTS USING NORMAL SUPPLY PROCEDURES. E. DISPOSITION OF HAZARDOUS MATERIAL - IAW ENVIRONMENTAL PROTECTION AGENCY DIRECTIVES AS IMPLEMENTED BY YOUR SERVICING ENVIRONMENTAL COORDINATOR (AR 200-1). 11. SPECIAL TOOLS AND FIXTURES REQUIRED - N/A. 12. APPLICATION - A. CATEGORY OF MAINTENANCE - AVUM. AIRCRAFT DOWNTIME WILL BE CHARGED TO AVUM. B. ESTIMATED TIME REQUIRED - (1) TOTAL OF 1 MAN-HOURS USING 1 PERSONS. (2) TOTAL OF 1 HOURS DOWNTIME FOR ONE END ITEM. C. ESTIMATED COST IMPACT OF STOCK FUND ITEMS TO THE FIELD NOMENCLATURE PART NO./NSN QUANTITY COST EA TOTAL $ BOLT NK4-13 5306-00-117-9897 6 $0.85 $5.10 TOTAL COST PER AIRCRAFT = $5.10 D. TB/MWOS TO BE APPLIED PRIOR TO OR CONCURRENTLY WITH THIS INSPECTION - N/A. E. PUBLICATIONS WHICH REQUIRE CHANGE AS A RESULT OF THIS INSPECTION - TM 55-2835-205-23P AND DMWR 55-2835-205 SHALL BE CHANGED TO REFLECT THIS MESSAGE. A COPY OF THIS MESSAGE SHALL BE INSERTED IN THE APPROPRIATE TM AND DMWR AS AUTHORITY TO IMPLEMENT THE CHANGE UNTIL THE PRINTED CHANGE IS RECEIVED. 13. REFERENCES - A. TM 55-2835-205-23P. B. DMWR 55-2835-205. 14. RECORDING AND REPORTING REQUIREMENTS - A. REPORTING COMPLIANCE SUSPENSE DATE (AIRCRAFT) - UPON ENTERING REQUIREMENTS OF THIS MESSAGE ON DA FORM 2408-13-1 ON ALL SUBJECT MDS AIRCRAFT, FORWARD A PRIORITY MESSAGE, DATAFAX OR EMAIL TO CDR, AMCOM, ATTN: AMSAM-SF-A (SOF COMPLIANCE OFFICER), R EDSTONE ARSENAL, AL 35898-5222 IAW AR 95-1. DATAFAX NUMBER IS DSN 897-2111 OR (256)313-2111. E-MAIL ADDRESS IS "SAFEADM@ REDSTONE.ARMY.MIL". THE REPORT WILL CITE THIS MESSAGE NUMBER, DATE OF ENTRY IN DA FORM 2408-13-1, THE AIRCRAFT MISSION DESIGN SERIES AND SERIAL NUMBERS OF AIRCRAFT IN NUMERICAL ORDER. B. TASK/INSPECTION REPORTING SUSPENSE DATE (AIRCRAFT) - NO SPECIAL REPORT OF THE RESULTS OF THIS INSPECTION IS REQUIRED. C. REPORTING MESSAGE RECEIPT (SPARES) - N/A D. TASK/INSPECTION REPORTING SUSPENSE DATE (SPARES). N/A E. THE FOLLOWING FORMS ARE APPLICABLE AND ARE TO BE COMPLETED IN ACCORDANCE WITH DA PAM 738-751, 15 JUN 92 - NOTE FOR ULLS-A UNITS, USE APPLICABLE "E" FORMS. (1) DA FORM 2408-5-1, EQUIPMENT MODIFICATION RECORD (APU). (2) DA FORM 2408-13, AIRCRAFT STATUS INFORMATION RECORD DA FORM 2408-18, EQUIPMENT INSPECTION LIST. (3) DA FORM 2408-13-1, AIRCRAFT INSPECTION AND MAINTENANCE RECORD. (4) DA FORM 2408-15, HISTORICAL RECORD FOR AIRCRAFT. (5) DA FORM 2408-18, EQUIPMENT INSPECTION LIST. NOTE ULLS-A USERS USE INSPECTION NUMBER 135 FOR THE 50 HOUR TORQUE CHECK. 15. WEIGHT AND BALANCE - N/A. 16. POINTS OF CONTACT - A. TECHNICAL POINT OF CONTACT FOR THIS MESSAGE IS MR. JOSEPH INGRAM, AMSAM-AR-EP, DSN 897-4994 OR COMMERCIAL (256)3134994, DATAFAX IS DSN 897-4961. E-MAIL IS "INGRAMJ@AVRDECR. REDSTONE.ARMY.MIL". B. LOGISTICAL POINT OF CONTACT FOR THIS MESSAGE IS NORM HUSTON, SFAE-AV-CH-L, DSN 897-4289 OR COMMERCIAL (256)313-4289, DATAFAX IS DSN 897-4348. E-MAIL IS "HUSTONN@PEOAVN.REDSTONE. ARMY.MIL". C. FORMS AND RECORDS POINT OF CONTACT FOR THIS MESSAGE IS MS. ANN WALDECK, AMSAM-MMC-RE-FD, DSN 746-5564 OR (256)876-5564, DATAFAX IS DSN 746-4904.E-MAIL IS "WALDECK-AB@REDSTONE. ARMY.MIL". D. SAFETY POINT OF CONTACT FOR THIS MESSAGE IS MR. HOWARD CHILTON, AMSAM-SF-A, DSN 897-2068 OR COMMERCIAL (256)313-2068, DATAFAX IS DSN 897-2111. E-MAIL IS "CHILTON-HL@REDSTONE. ARMY.MIL". ALTERNATE POINT OF CONTACT IS TENG OOI, AMSAM-SF-A, DSN 897-2094 OR COMMERCIAL (256)313-2094, DATAFAX IS DSN 897-2111. E-MAIL IS "OOI-TK@REDSTONE.ARMY.MIL". E. FOREIGN MILITARY SALES RECIPIENTS REQUIRING CLARIFICATION OF ACTION ADVISED BY THIS MESSAGE SHOULD CONTACT CW5 JOSEPH L. WITTSTROM, SECURITY ASSISTANCE MANAGEMENT, AMSAMSA, DSN 897-0681 OR (256) 313-0681. EMAIL IS "WITTSTROMJL@REDSTONE. ARMY.MIL". MR. RONNIE W. SAMMONS, AMSAM-SA-CS-NF, DSN 897-0869 OR (256)313-0869. DATAFAX IS DSN 897-0411 OR (256) 313-0411. EMAIL IS "SAMMONS-RW@ REDSTONE.ARMY.MIL". (HUNTSVILLE, AL IS GMT MINUS 6 HRS). F. AFTER HOURS CONTACT THE AMCOM COMMAND OPERATIONS CENTER (COC) DSN 897-2066/7 OR (256)313-2066/7.