01 16 041225Z JUN 01 PP PP UUUU AA ZYUW FROM :CDRAMCOM REDSTONE ARSENAL AL//AMSAM-SF-A// TO :AIG 8881 :AIG 9004 :AIG 7515 :AIG 7471 :AIG 12124 :CDRATC ABERDEEN PROVING GROUND MD//CSTE-DTC-AT-WC-W// :USDAO NICOSIA CY//11 CAB LNO// :CDR160THSOAR FT CAMPBELL KY//AOAV-SI// :CDRBGAD RICHMOND KY//SIOBG-GC// :RAYTHEON RANGE SYSTEMS ENGINEERING KWAJALEIN MH//PAT2// :CHIEF ARMY AIR DIV HOLLOMAN AFB NM//CSTE-DTC-WS-NRO-F// :USDOCO LANDSOUTHEAST IZMIR TU//AV// INFO :CDRUSARDSG CANBERRA ACT AS//AMXIP-AS// :129RQW MOFFETT FEDERAL AIRFIELD CA//MAQ// :CDRMDW WASHINGTON DC//ANLG-LS// :FAA NATIONAL HQ WASHINGTON DC//AIR-100// :FBI WASHINGTON DC//CIRG-SOU AVIATION// :HQ USAF WASHINGTON DC//AQQU// :US CUSTOMS SERVICE WASHINGTON DC//AVIATION : OPERATIONS// :CDRUSARDSG LONDON UK//AMXSN-UK-SE// :COMNAVSAFECEN NORFOLK VA//113/111/122// XMT : ACCT : TEXT :UNCLAS SUBJECT - AVIATION SAFETY ACTION MESSAGE, MAINTENANCE MANDATORY, RCS CSGLD-1860(R1), AVIATION GROUND SUPPORT EQUIPMENT (AGSE), HYDRAULIC FLUID CONTAMINATION CONTROL, GEN-01-ASAM-04. NOTE THIS MESSAGE IS ISSUED IAW AR 95-1, 1 SEP 97, CHAPTER 6. THIS MESSAGE HAS NOT BEEN TRANSMITTED TO UNITS SUBORDINATE TO ADDRESSEES. ADDRESSEES SHOULD IMMEDIATELY RETRANSMIT THIS MESSAGE TO ALL SUBORDINATE UNITS, ACTIVITIES OR ELEMENTS AFFECTED OR CONCERNED. THE RETRANSMITTAL SHALL REFERENCE THE MESSAGE. ACTION ADDRESSEES WILL IMMEDIATELY VERIFY THIS TRANSMISSION TO CDR, AMCOM, ATTN: AMSAM-SF-A (SOF COMPLIANCE OFFICER). 1. PRIORITY CLASSIFICATION - NOTE IAW AR 95-1, PARAGRAPH 6-14A, MACOM COMMANDERS MAY AUTHORIZE TEMPORARY EXCEPTION FROM MESSAGE REQUIREMENTS. EXCEPTION MAY ONLY OCCUR WHEN COMBAT OPERATIONS OR MATTER OF LIFE OR DEATH IN CIVIL DISASTERS OR OTHER EMERGENCIES ARE SO URGENT THAT THEY OVERRIDE THE CONSEQUENCES OF CONTINUED AIRCRAFT OPERATION. 2. TASK/INSPECTION SUSPENSE DATE - COMPLETE THE INSPECTION IAW PARAGRAPH 8 PRIOR TO NEXT USE OF AGSE (HYDRAULIC MODULE). 3. REPORTING COMPLIANCE SUSPENSE DATE - N/A. 4. SUMMARY OF PROBLEM - A. TO COMPLY WITH WATER CONTENT AND CLEANLINESS REQUIREMENTS CONTAINED IN PREVIOUS MESSAGES, AGSE THAT SUPPORT ARMY AIRCRAFT ARE REQUIRED TO BE MAINTAINED AT SUBSTANTIALLY HIGHER LEVELS OF PURITY. WATER CONTENT AND CLEANLINESS REQUIREMENTS OF THESE MESSAGES CANNOT BE MET WITHOUT PROPER MAINTENANCE AND CAREFUL SAMPLING PROCEDURES. B. MANPOWER/DOWNTIME AND FUNDING IMPACTS - SEE PARA 12. C. THE PURPOSE OF THIS MESSAGE IS TO - (1) PROVIDE DETAILED OPERATION, MAINTENANCE, AND RECURRING SAMPLING REQUIREMENTS FOR ALL HYDRAULIC GROUND POWER UNITS THAT ARE CONNECTED TO ARMY AIRCRAFT. (2) SUPERSEDE PORTIONS OF CH-47-00-ASAM-03 (PARA 8C AND 9A(5)), OH-58-00-ASAM-05 (PARA 9D), AND AH-64-01-ASAM-05 (PARA 4C(1), 8B, AND 9A), RELATING TO HYDRAULIC AGSE WITH RESERVOIRS, (HYDRAULIC TEST STANDS, AVIATION GROUND POWER UNITS (AGPU), ETC.) SAMPLING REQUIREMENTS. (3) CHANGE SAMPLING INTERVAL FOR AGSE FROM 7 DAYS TO 30 DAYS. 5. END ITEMS TO BE INSPECTED - ALL HYDRAULIC AGSE USED TO APPLY EXTERNAL HYDRAULIC POWER TO ARMY AIRCRAFT, INCLUDING ALL HYDRAULIC TEST STANDS (DEPOT AND ORGANIZATIONAL). AGPU'S THAT ARE UNSERVICEABLE OR HAVE THE HYDRAULIC PUMP DRIVE DISENGAGED, SPACER INSTALLED, ARE EXEMPT FROM SAMPLING REQUIREMENTS. 6. ASSEMBLY COMPONENTS TO BE INSPECTED - N/A. 7. PARTS TO BE INSPECTED - N/A. 8. INSPECTION PROCEDURES - A. THE HYDRAULIC FLUID ON ALL SOURCES OF AIRCRAFT EXTERNAL HYDRAULIC POWER WILL BE SAMPLED AND PROCESSED PER TB 43-0106. ALL OPERATIONAL HYDRAULIC GROUND POWER UNITS, INCLUDING HYDRAULIC TEST STANDS (DEPOT AND ORGANIZATIONAL), WILL BE SAMPLED EVERY 30 DAYS. ALL HYDRAULIC GROUND POWER UNITS THAT HAVE NOT BEEN SAMPLED IN THE LAST 30 DAYS WILL BE INSPECTED AND SAMPLED IAW THIS MESSAGE PRIOR TO NEXT USE. B. SPECIFIC INSPECTION REQUIREMENTS FOR THE AGPU - (1) INSPECT AGPU RESERVOIR VENT DRYER TO ENSURE 25 PERCENT OF THE FULL CANISTER CONTAINS DESICCANT THAT IS BLUE IN COLOR. IF NOT, REPLACE WITH NEW DESICCANT NSN 6650-00-680-2233 OR NSN 6650-00-290-0042. (2) INSPECT AGPU ACCESSORIES TO ENSURE THAT 30-FOOT PRESSURE AND RETURN HOSES, THE 10-FOOT PRESSURE AND RETURN ADAPTER HOSES, AND THE DUAL SERVICE MANIFOLD ARE AVAILABLE. (3) ENSURE ALL HYDRAULIC HOSE CONNECTORS ON THE AGPU HYDRAULIC CONTROL PANEL, THE DUAL SERVICE MANIFOLD, AND HOSES ARE PROTECTED FROM CONTAMINATION WITH A CAP OR PLUG WHEN NOT IN USE. ORDER REPLACEMENTS AS LISTED IN TM 55-1730-229-24P. NOTE OPERATION OF THE AGPU IS TO BE PERFORMED ONLY BY A TRAINED/QUALIFIED OPERATOR. REFER TO INSTRUCTION PLATE ON HYDRAULIC CONTROL PANEL DOOR FOR IMPORTANT SETUP AND SHUTDOWN PROCEDURES FOR THE AGPU HYDRAULIC SYSTEM. IT IS NOT NECESSARY TO ATTACH HOSES TO TAKE THE SAMPLE. NOTE TO REDUCE CONTAMINATION AT HOSE CONNECTION WHEN PERFORMING SELF-FILTERING AND PURGING OPERATIONS, IF REQUIRED, PLACE THE DUAL SERVICE MANIFOLD ON A LARGE DRIP PAN OR OTHER CLEAN SURFACE. INSPECT EACH HOSE COUPLING FOR VISIBLE CONTAMINATION AND WIPE CLEAN PRIOR TO MAKING THE CONNECTION. CONNECT REMOVED PLUGS TO REMOVED CAPS AS EACH CONNECTION IS MADE. C. SPECIFIC HYDRAULIC FLUID SAMPLING PROCEDURES FOR THE AGPU. IF THE AGPU HAS NOT BEEN SAMPLED IN THE LAST 30 DAYS OR IF THE AOAP LAB REQUESTS A RESAMPLE, PERFORM HYDRAULIC SYSTEM SELF-FILTERING AND PURGING OPERATION IAW TM 55-1730-229-12, PAGE 3-23, PARA 3-10, THEN PROCEED TO PARAGRAPH 8C(6) OF THIS MESSAGE TO OBTAIN THE SAMPLE. (1) CHECK PROPER RESERVOIR LEVEL AND ENSURE RESERVOIR SELECTOR IS SET TO AGPU. CLOSE ALL SHUTOFF VALVES. OPEN GAUGE SHUTOFF VALVE 1/4 TURN. SET RETURN BYPASS TO BYPASS. (2) START AGPU ENGINE AND IMMEDIATELY CHECK THAT APPROXIMATELY 500 PSI IS INDICATED ON HIGH PRESSURE OUTPUT GAUGE. SET POWER SWITCH TO ON. (3) INCREASE OUTPUT PRESSURE TO 1000 PSI. OPEN HIGH PRESSURE AND RETURN BLEED VALVES TO REMOVE AIR. CLOSE VALVE WHEN RED MIST IN VIEW PORTS IS SOLID RED IN COLOR. (4) INCREASE PRESSURE TO 2000 PSI. OPEN HIGH PRESSURE BYPASS 1/4 TURN. IF SYSTEM READY LIGHT IS NOT ON, WAIT UNTIL THE TEMPERATURE RISES 10 DEGREES, THEN OPEN VALVE ANOTHER 1/4 TURN. REPEAT UNTIL SYSTEM READY LIGHT COMES ON. OPEN THE HIGH PRESSURE BYPASS UNTIL THE PRESSURE STARTS TO DROP. CONTINUE TO OPERATE FOR A MINIMUM OF 5 MINUTES. (5) CLOSE HIGH PRESSURE BYPASS, REDUCE PRESSURE TO 500 PSI, SET POWER SWITCH TO OFF, AND SHUTDOWN ENGINE. (6) SAMPLE THE FLUID IMMEDIATELY AFTER SHUTDOWN. THE AGPU SHOULD BE LOCATED IN A SHELTERED AREA AS FREE AS POSSIBLE FROM RAIN OR AIRBORNE CONTAMINATION. TAKE A SAMPLE FROM THE HIGH PRESSURE GAUGE CALIBRATION PORT ON THE AGPU HYDRAULIC CONTROL PANEL. USE AN EMPTY QUART CAN OR SIMILAR WASTE RECEPTACLE TO COLLECT FLUID THAT WILL BE DRAINED FROM THE PORT BEFORE AND AFTER THE SAMPLE IS TAKEN. (7) USE A 3-OUNCE AOAP PLASTIC BOTTLE TO COLLECT SAMPLE AS FOLLOWS - (A) CLOSE THE GAUGE SHUTOFF VALVE AND FULLY OPEN THE HIGH PRESSURE BLEED VALVE. REMOVE THE CAP FROM THE HIGH PRESSURE GAUGE CALIBRATION PORT. OPEN THE HIGH PRESSURE GAUGE SHUTOFF VALVE AND DRAIN APPROXIMATELY 3 OUNCES OF FLUID INTO THE WASTE RECEPTACLE. THIS PROCEDURE SERVES TO FLUSH AWAY ANY CONTAMINANTS IN THE SAMPLING LINE AND ANY CONTAMINANTS GENERATED BY VALVE OPERATIONS. (B) WITHOUT INTERRUPTING THE FLOW OF FLUID, PLACE A CLEAN 3-OZ AOAP SAMPLE BOTTLE UNDER THE FLUID STREAM AND PARTIALLY FILL BOTTLE (APPROX. 1/4 INCH FROM BOTTOM). REMOVE BOTTLE FROM STREAM AND SHUT OFF FLOW. (C) CAP BOTTLE AND SHAKE VIGOROUSLY. REMOVE CAP AND DRAIN BOTTLE INTO WASTE RECEPTACLE. (D) RINSE THE BOTTLE A SECOND TIME BY OPENING GAUGE SHUTOFF VALVE AND REPEATING STEPS (B) AND (C). (E) OPEN THE HIGH PRESSURE GAUGE SHUTOFF VALVE AND AGAIN ALLOW AN INITIAL QUANTITY OF APPROXIMATELY 3 OUNCES TO FLOW INTO WASTE RECEPTACLE. (F) WITHOUT INTERRUPTING THE FLOW OF FLUID, TAKE THE SAMPLE BY PLACING THE RINSED BOTTLE UNDER THE FLUID STREAM AND FILL BOTTLE TO ITS SHOULDER LEAVING APPROXIMATELY 1/2-INCH AIR SPACE FROM TOP. (G) REMOVE THE SAMPLE BOTTLE FROM THE STREAM AND IMMEDIATELY CAP THE BOTTLE. CLOSE THE SHUTOFF VALVE ONLY AFTER THE SAMPLE BOTTLE HAS BEEN REMOVED. (H) REINSTALL THE CAP ON THE HIGH PRESSURE GAUGE CALIBRATION PORT AND OPEN THE GAUGE SHUTOFF VALVE 1/4 TURN. (I) LABEL BOTTLE IDENTIFYING AGPU SAMPLED. (J) COMPLETE DD FORM 2026, OIL ANALYSIS REQUEST. IN THE EQUIPMENT MODEL/APL BLOCK, ENTER THE TYPE OF AIRCRAFT SUPPORTED (I.E. AH-64D, OH-58D, MULTI). IN THE "END ITEM MODEL/HULL NO." BLOCK, ENTER "MEP-360A" FOR BOTH THE A AND D MODEL AGPU'S. USE COMMERCIAL MODEL NUMBER FOR OFF-THE-SHELF POWER UNITS. IN THE END ITEM SER. NO./EIC BLOCK, ENTER THE 4 DIGIT NUMBER FROM THE AGPU IDENTIFICATION PLATE FOLLOWED BY AN "H" (I.E. 0054H). DO NOT USE MOTOR POOL NUMBER. (K) PLACE SAMPLES INTO SAMPLE MAILER KIT AND SEND TO THE UNIT'S AOAP LABORATORY FOR ANALYSIS. (L) COMPLETE DA FORM 2408-20. D. IF OFF-THE-SHELF, NON-STANDARD HYDRAULIC TEST STANDS OR GROUND POWER UNITS ARE TO BE USED, SAMPLING PROCEDURES FOR THESE UNITS SHOULD FOLLOW THOSE PROVIDED IN PARA 8C FOR THE AGPU. THE HYDRAULIC FLUID, INCLUDING THAT IN THE GSE RESERVOIR SHOULD BE WARM AND RECENTLY CIRCULATED THROUGH THE HIGH PRESSURE FILTER PRIOR TO SAMPLING. SAMPLING WILL NORMALLY BE TAKEN DOWN STREAM FROM THE HIGH PRESSURE OUTPUT FILTER. 9. CORRECTION PROCEDURES - A. CONTAMINATION OF THE HYDRAULIC FLUID CAN BE CONTROLLED THROUGH CAREFUL ATTENTION TO ALL EQUIPMENT AND PROCEDURES USED TO SERVICE AND MAINTAIN AIRCRAFT HYDRAULIC SYSTEMS. HYDRAULIC FLUID MUST BE KEPT IN SEALED CONTAINERS TO LIMIT ABSORPTION OF WATER AND CONTAMINATION WITH AIRBORNE PARTICLES. USE OF HYDRAULIC SERVICING UNITS/DISPENSERS THAT AUTOMATICALLY SEAL THE FLUID CONTAINER AS IT IS PIERCED TO KEEP OUT MOISTURE AND CONTAMINATION IS RECOMMENDED. ALL HYDRAULIC HOSE CONNECTORS WILL BE COVERED WITH A CAP OR PLUG WHEN NOT IN USE. METAL PLUGS WITH O-RING SEALS ARE RECOMMENDED IN PLACE OF PLASTIC CAPS. SEE PARA 10C FOR RECOMMENDED ITEMS FOR USE IN THIS APPLICATION. B. THE FOLLOWING PROCEDURES ARE REQUIRED IF THE AOAP RECOMMENDS THE AGPU BE DRAINED AND REFILLED BECAUSE OF EXCESSIVE PARTICULATE CONTAMINATION - (1) IF THE AGPU MAINTENANCE RECORDS INDICATE THAT THE FILTER ELEMENTS HAVE BEEN REPLACED IN THE LAST 6 MONTHS REPEAT THE HYDRAULIC SYSTEM SELF-FILTERING AND PURGING OPERATION IAW TM 55-1730-229-12, PAGE 3-23, PARA 3-10. (2) IF FILTER ELEMENTS HAVE NOT BEEN REPLACED IN THE LAST 6 MONTHS, DRAIN THE AGPU AND REPLACE BOTH THE LOW PRESSURE AND HIGH PRESSURE FILTER ELEMENTS AND REFILL WITH CLEAN HYDRAULIC FLUID IAW TM 55-1730-229-12, PARA 4-94 AND PARA 3-9 RESPECTIVELY. (3) REPEAT STEPS IN 8C(6)AND(7) TO TAKE AN ADDITIONAL SAMPLE. THE AGPU IS NOW CLEARED FOR USE. C. THE FOLLOWING PROCEDURES ARE REQUIRED IF THE AOAP RECOMMENDS THE AGPU BE DRAINED AND REFILLED BECAUSE OF EXCESSIVE WATER CONTENT - (1) IF A HYDRAULIC PURIFIER IS AVAILABLE PURIFY THE AGPU IN ACCORDANCE WITH THE PROCEDURES PROVIDED WITH THE PURIFIER. THE AGPU IS NOW CLEARED FOR USE. (2) IF NO HYDRAULIC PURIFIER IS AVAILABLE, REPEAT THE SAMPLING PROCEDURE IN PARAGRAPH 8C WITH THE FOLLOWING CHANGES - (A) AFTER THE SYSTEM READY LIGHT COMES ON, CLOSE THE HIGH PRESSURE BYPASS AND INCREASE PRESSURE TO 3300 PSI. OPEN BYPASS UNTIL THE PRESSURE DROPS TO 3000 PSI. (B) OPEN THE RESERVOIR VENT. OPERATE AT 3000 PSI AND OBSERVE FLUID TEMPERATURE. IF POSSIBLE MAINTAIN TEMPERATURE ABOVE 200 DEGREES F. OPEN BYPASS VALVE SO THAT THE FLUID TEMPERATURE DOESN'T EXCEED 240 DEGREES F. AFTER 15 MINUTES AT 200-240 DEGREES F, OR MAXIMUM TEMPERATURE ACHIEVABLE, CLOSE RESERVOIR VENT. (C) CLOSE HIGH PRESSURE BYPASS, REDUCE PRESSURE TO 500 PSI, SET POWER SWITCH TO OFF, AND SHUTDOWN ENGINE. (D) REPEAT STEPS IN PARA 8C(6) AND (7) TO TAKE AN ADDITIONAL SAMPLE. D. IF THE AOAP AGAIN RECOMMENDS THE AGPU BE DRAINED AND REFILLED BECAUSE OF EXCESSIVE WATER CONTENT AFTER THE PROCESS IN 9C(2) HAS BEEN PERFORMED, DRAIN THE AGPU AND ITS HOSES AND REFILL WITH CLEAN HYDRAULIC FLUID IAW TM 55-1730-229-12, PARA 3-9. REPEAT STEPS 8C(6) AND (7) OF THIS MESSAGE TO TAKE AN ADDITIONAL SAMPLE. THE AGPU IS NOW CLEARED FOR USE. E. UNITS OWNING NON-STANDARD HYDRAULIC GROUND POWER UNITS MUST COMPLETE THE AOAP CANDIDATE ENROLLMENT NOMINATION DATA SHEETS, AMC FORM 2889-R-E, TO REQUEST AOAP SUPPORT. FORM MAY BE OBTAINED ONLINE AT "WWW.AMC.ARMY.MIL/NEWS/NEWS.HTM" (USE LOWER CASE LETTERS IN THIS WEB ADDRESS). SUBMIT FORM TO PM-AOAP POC LISTED IN PARAGRAPH 16B(2). 10. SUPPLY/PARTS AND DISPOSITION - A. PARTS REQUIRED - N/A. B. REQUISITIONING INSTRUCTIONS - N/A C. BULK AND CONSUMABLE MATERIALS - NOMENCLATURE PART NUMBER NSN BOTTLES, OIL SAMPLE (120 EA) MIL-B-44054 8125-01-082-9697 SAMPLING MAILER KIT MIL-B-44054A 8125-01-193-3440 (24 BOTTLES, PLASTIC SHIPPING SACKS, AND MAILING CARTONS) DESICCANT, 1.5 LB CAN MIL-D-3716 6650-00-680-2233 DESICCANT, 5.0 LB CAN MIL-D-3716 6650-00-290-0042 FILTER ELEMENT, FLUID 935852Q 4330-01-484-0896 (HP, 2-MICRON), (REPLACES HP, 3-MICRON, 4330-01-220-3020) FILTER ELEMENT, FLUID 935853Q 4330-01-484-0891 (LP, 5-MICRON). (REPLACES LP 10-MICRON, 4330-01-220-3021) PLUG, QUICK DISCONNECT 155S9-8D 4720-00-576-5545 (REPLACES CAP, PROTECTIVE, DUST & MOIST, 5340-01-269-4527) PLUG, PROTECTIVE, 155S9-12D 5340-00-561-1545 DUST & MOIST (REPLACES CAP, PROT ASSY, 5340-01-270-2985) HYDRAULIC FLUID (1-GAL CAN) MIL-PRF-83282 9150-01-149-7432 HYDRAULIC FLUID (10-GAL DRUM) MIL-PRF-83282 9150-01-009-7709 D. DISPOSITION - N/A. E. DISPOSITION OF HAZARDOUS MATERIAL - IAW ENVIRONMENTAL PROTECTION AGENCY DIRECTIVES AS IMPLEMENTED BY YOUR SERVICING ENVIRONMENTAL COORDINATOR (AR 200-1). 11. SPECIAL TOOLS AND FIXTURES REQUIRED - N/A. 12. APPLICATION - A. CATEGORY OF MAINTENANCE - AVUM. B. ESTIMATED TIME REQUIRED - (1) TIME TO COMPLETE INSPECTION - (A) TOTAL OF 0.6 MAN-HOURS USING 2 PERSONS. (B) TOTAL OF 0.3 HOURS DOWNTIME FOR ONE END ITEM. (2) TIME FOR REPAIR/REPLACEMENT - (A) TOTAL OF 2 MAN-HOURS USING 1 PERSON. (B) TOTAL OF 2 HOURS DOWNTIME FOR ONE END ITEM. C. ESTIMATED COST IMPACT TO THE FIELD - N/A. D. TB/MWOS TO BE APPLIED PRIOR TO OR CONCURRENTLY WITH THIS INSPECTION - N/A. E. PUBLICATIONS WHICH REQUIRE CHANGE AS A RESULT OF THIS INSPECTION - TM 55-1730-229-12 AND TM 55-1730-229-24P SHALL BE CHANGED TO REFLECT THIS MESSAGE. A COPY OF THIS MESSAGE SHALL BE INSERTED IN THE APPROPRIATE TM AS AUTHORITY TO IMPLEMENT THE CHANGE UNTIL THE PRINTED CHANGE IS RECEIVED. 13. REFERENCES - A. TB 43-0106. B. TM 55-1730-229-12. C. TM 55-1730-229-24P. D. DA PAM 738-750. 14. RECORDING AND REPORTING REQUIREMENTS - DA FORM 2408-20 SHALL BE COMPLETED IAW DA PAM 738-750, 1 AUG 94. 15. WEIGHT AND BALANCE - N/A. 16. POINTS OF CONTACT - A. TECHNICAL POINTS OF CONTACT FOR THIS MESSAGE ARE - (1) JEROME SMITH, AMSAM-RD-AE-I-C-G, DSN 897-4926 OR (256) 313-4926, DATAFAX IS DSN 897-4923. E-MAIL IS "JEROME.SMITH@REDSTONE.ARMY.MIL". (2) BILL GURSKY, AMSAM-MMC-VS-AM, DSN 897-1449 OR (256) 313-1449, DATAFAX IS DSN 897-1444 OR (256) 313-1444. E-MAIL IS "WILLIAM.GURSKY@REDSTONE.ARMY.MIL". B. LOGISTICAL POINTS OF CONTACT FOR THIS MESSAGE ARE - (1) WILLIAM SLATE, AMSAM-DSA-AS-AG, DSN 746-2282 OR (256) 876-2282, DATAFAX IS DSN 778-0572 OR (256) 842-0572. E-MAIL IS "WILLIAM.SLATE@REDSTONE.ARMY.MIL". (2) AOAP POINT OF CONTACT IS DANIEL MCELROY, AMXLS-LA, DSN 645-6915 OR (256) 955-6915 DATAFAX 746-9344 OR (256) 876-9344. E-MAIL IS "AOAP@LOGSA.ARMY.MIL". C. SAFETY POINTS OF CONTACT ARE - (1) PRIMARY - RANDALL RUSHING (SAIC), AMSAM-SF-A, DSN 897-2092 OR (256) 313-2092, DATAFAX IS DSN 897-2111 OR (256) 313-2111. E-MAIL IS "RANDALL.RUSHING@REDSTONE.ARMY.MIL". (2) ALTERNATE - HOWARD CHILTON, AMSAM-SF-A, DSN 897-2068 OR (256) 313-2068, DATAFAX IS DSN 897-2111 OR (256) 313-2111. E-MAIL IS "HOWARD.CHILTON@REDSTONE.ARMY.MIL".. D. FOREIGN MILITARY SALES RECIPIENTS REQUIRING CLARIFICATION OF ACTION ADVISED BY THIS MESSAGE SHOULD CONTACT - (1) PRIMARY - RONNIE W. SAMMONS, AMSAM-SA-CS-NF, DSN 897-6856 OR (256) 313-6856. DATAFAX IS DSN 897-6630 OR (256) 313-6630. EMAIL IS "RONNIE.SAMMONS@REDSTONE.ARMY.MIL". (2) ALTERNATE - PAUL W. TARR, AMSAM-SA-CS-NF, DSN 897-6861 OR (256) 313-6861. DATAFAX IS DSN 897-6630 OR (256) 313-6630. EMAIL IS "PAUL.TARR@REDSTONE.ARMY.MIL". E. AFTER HOURS CONTACT THE AMCOM COMMAND OPERATIONS CENTER (COC) DSN 897-2066/7 OR (256) 313-2066/7.