SYNOPSIS GEN-93-ASAM-12 AVIATION SAFETY ACTION MESSAGE, MAINTENANCE MANDATORY, PITOT STATIC SYSTEM TESTER, CASE GROUNDING. 191400Z AUG 93, HOWARD CHILTON, AMSAT-C-XS, X2085. NOTE: Enter a + <CR> to exit or <SPACEBAR> to view the entire message. (NON-REPORTING) . 01 10 191400Z AUG 93 PP PP UUUU :CDRATCOM ST LOUIS MO//AMSAT-C-XS// TO :AIG 6713 :AIG 9004 :AIG 8708 :AIG 9042 :AIG 7515 :DCM APMO OZARK AL//DCMDS-RCQA// :AMEMBASSY BOGOTA CO//NAS/MLO// :USDAO NICOSIA CY//11 CAB LNO// :AMEMBASSY ABU DHABI//USLO// :NOAA OFFICE OF AIRCRAFT OPERATIONS MIAMI FL :CDROSAC EASTERN REGION FT MCPHERSON GA//ANAV-ER// :ODC ATHENS GR//ODCSA-A// :CDR4THBN228THAVN SOTO CANO HO//AVN-AMO// :102DARMY SCOTT AFB IL//AFKB-AC-CJ-ASF// :AMEMBASSY ROME IT//ODC/PASS TO HQ MFO// :CDR160TH SOAR FT CAMPBELL KY//AOAV-SI// :COMNAVAIRWARCENACDIV PATUXENT RIVER MD//TP90// :USDAO MEXICO CITY MX//MLO/NAS// :DIRAAOD HOLLOMAN AFB NM//STEWS-AA/GE GS// :CDRAMCCOM PICATINNY ARSENAL NJ//AMSMC-AV-D// :AFSAC FLO WRIGHT PATTERSON AFB OH//KS/SN/SP/VE// :USCS CNAC OKLAHOMA CITY OK//AMI// :FORCE COMMANDER SINAI MFO HQ IL TELEX 606342535 ://PASS TO SSO AVSM/SO AIR// :USLOT TUNIS TS //AIR FORCE SECTION// :CDROSAC WESTERN REGION FT HOOD TX//ANAV-WR// :DPRO BELL HELICOPTER FORT WORTH TX//DCMDS-RBQ/RBDF// :CDROSAC FT BELVOIR VA//ANAV-OS/ANAV-RW-M/ANAV-CR// INFO :TSM ATK HEL FT RUCKER AL//ATZQ-TSM-A// :210RQS KULIS ANGB AK//SE// :ARS MCCLELLAN AFB CA//LGM// :129RQG MOFFETT FLD CA//MAQ// :129RQS MOFFETT FLD CA//DOV// :HSL FOUR ONE NORTH ISLAND CA :LOG CON OTTAWA ONT CAN//DTHEM 6-3// :FBI WASHINGTON DC//PASS TO AVIATION SUPERVISOR// :HQ USAF WASHINGTON DC//AQQU// :SEC STATE WASHINGTON DC//NEA/MFO// :US CUSTOMS SERVICE WASHINGTON DC//AVIATION :OPERATIONS// :41RQS PATRICK AFB FL//CC// :71ARQS PATRICK AFB FL//CC// :301RQS PATRICK AFB FL//SE// :1SOG HURLBURT FIELD FL//CC// :AFSOC HURLBURT FIELD FL//DOT/DOVR/LGMA/SE// :NAVAIRSYSCOM DET PMA PENSACOLA FL//PMA225// :NAVAVNDEPOT PENSACOLA FL//310B// :WR-ALC ROBINS AFB GA//LUHA// :CDR AMC EUROPE SECKENHEIM GE//AMXEU-L-AAH-MFT-E// :HQ PACAF HICKAM AFB HI//DO/LGM// :56ARS KEFLAVIK IC//MA// :HQ AMC SCOTT AFB IL//LG/DO/DOV/DOT/LGM/DOX// :39RQS MISAWA AB JA//MA// :38RQS OSAN AB KOR//LGM// :FAA NORTHEAST RGN HQ BURLINGTON MA//ANE-150// :48RQS HOLLOMAN AFB NM//MA// :102RQS GABRESKI APT NY//DOLS// :106CAMS GABRESKI APT NY//MA// :66RQS NELLIS AFB NV//MA// :CDR WHITE SANDS MISSILE RANGE NM//STEWS-AA// :CUSALAO FT BLISS TX//AMXLA-T-BL/DEPT OF JUSTICE INS :BORDER PATROL// :304RQS PORTLAND IAP OR//SE// :DIR OTSA FT BLISS TX//CSTE-OTA// :CDRIIICORPS FT HOOD TX//SFAE-AV-AAH-MFT-H// :CDRUSARDSG LONDON UK//AMXSN-UK-SE// :PROJ MGR NVEO FT BELVOIR VA//SFAE-IEW-NV// :PMSW VHFS WARRENTON VA//SFAE-IEW-SG// :HQ ACC LANGLEY AFB VA//DOH/LGRC// XMT :CH FMS CANBERRA AS :USDAO DHAKA BG :USDAO RANGOON BM :USDAO COLOMBO CE :USDAO SUVA FJ :OMADP JAKARTA ID :DSA NEW DELHI IN :USDAO ROME IT :USDAO ANTANANARIVO MA :CDRATCOM ST LOUIS MO//AMSAT-C-XS// :SAO KUALA LUMPUR MY :USDAO KATMANDU NP//SAO// ACCT : TEXT :UNCLAS SUBJECT - AVIATION SAFETY ACTION MESSAGE, MAINTENANCE MANDATORY. RCS CSGLD-1860(R1), PITOT STATIC SYSTEMS TESTER, CASE GROUNDING, (GEN-93-ASAM-11). NOTE - THIS IS AN AVIATION SAFETY ACTION MESSAGE AND HAS NOT BEEN TRANSMITTED TO UNITS SUBORDINATE TO ADDRESSEES. ADDRESSEES SHOULD IMMEDIATELY RETRANSMIT THIS MESSAGE TO ALL SUBORDINATE UNITS, ACTIVITIES OR ELEMENTS AFFECTED OR CONCERNED. THE RETRANSMITTAL SHALL REFERENCE THE MESSAGE. ACTION ADDRESSES WILL IMMEDIATELY VERIFY THIS RETRANSMISSION TO COMMANDER, ATCOM, ATTN: AMSAT-C-XS (SOF COMPLIANCE OFFICER). 1. PRIORITY CLASSIFICATION - N/A 2. TASK/INSPECTION SUSPENSE DATE - WITHIN 10 DAYS. 3. REPORTING COMPLIANCE SUSPENSE DATE - N/A. 4. SUMMARY OF PROBLEM - A. THERE HAVE BEEN REPORTS OF OPERATORS GETTING ELECTRICAL SHOCKS BY TOUCHING THE CASE OF THE MOST RECENTLY FIELDED PITOT STATIC TESTER WHILE IN USE. THE POTENTIAL ON THESE CASES HAS BEEN MEASURED AT APPROXIMATELY 60 VOLTS WHEN CONNECTED TO A 115 VOLT, 60 HERTZ POWER SOURCE. THIS RESULTS FROM THE POWER CORDS NOT HAVING A GROUND WIRE. B. FOR MANPOWER/DOWNTIME AND FUNDING IMPACTS SEE PARA 12. C. THE PURPOSE OF THIS MESSAGE IS TO ALERT USERS OF THIS POTENTIAL SAFETY HAZARD, TO PROVIDE INSTRUCTIONS ON HOW TO GET THE POWER CABLES USED WITH THESE TESTERS MODIFIED (TO GROUND THE CASE) AND TO REQUIRE A SEPARATE CASE GROUND WIRE IF THE TESTER MUST BE USED PRIOR TO THIS MODIFICATION. 5. END ITEMS TO BE INSPECTED - TESTER, PITOT STATIC SYSTEMS, NSN 4920-01-182-1972, P/N 3400-0003, CAGE 59413. 6. ASSEMBLY COMPONENTS TO BE RETURNED - NOMENCLATURE PART NO. NSN AC POWER 115 VOLT 50-500 HZ 1 PHASE 80-10013 NOT YET ASSIGNED POWER CABLE CORD ASSEMBLY 80-10113 AC POWER ADAPTER 80-10110 NOT YET ASSIGNED 3 PHASE ADAPTER CORD 80-10112 NOT YET ASSIGNED 7. PARTS TO BE INSPECTED - N/A 8. INSPECTION PROCEDURES - N/A 9. CORRECTION PROCEDURES - A. OPERATIONAL. WARNING THE UNGROUNDED CASE OF THE PITOT STATIC TESTER EXPOSES. OPERATORS TO A 60 VOLT ELECTRICAL SHOCK IN USE. ALL OPERATING PERSONNEL ARE TO BE INSTRUCTED TO INSURE THAT THE TESTER CASE IS GROUNDED PRIOR TO APPLYING POWER. UNTIL THE AC POWER CABLES ARE MODIFIED, THE USER SHALL ENSURE THAT THE PITOT STATIC TESTER IS GROUNDED BY CONNECTING A WIRE BETWEEN A COMMON GROUND POINT AND THE TESTER CASE. B. REPAIR. THE THREE AC POWER CABLES WILL BE MODIFIED BY THE PITOT STATIC SYSTEM SUPPLIER AND RETURNED TO THE UNIT WITHOUT CHARGE. THE VENDOR, INSTRUMENT TECH, HAS INDICATED AN APPROXIMATE 24 HOUR TURNAROUND REPAIR TIME ON RETURNED CABLES. AN INFORMATIONAL CATEGORY II QUALITY DEFICIENCY REPORT (QDR) IS REQUIRED. 10. SUPPLY/PARTS AND DISPOSITION - A. PARTS REQUIRED - N/A. B. REQUISITIONING INSTRUCTIONS - N/A. C. BULK AND CONSUMABLE MATERIALS - N/A D. DISPOSITION - THE THREE AC POWER CABLES LISTED IN PARAGRAPH 6 ARE TO BE SHIPPED TO: INSTRUMENT TECH CORP. ATTN: WILLIAM WASINGER, QUALITY CONTROL MANAGER, 15060 BELTWOOD PARKWAY EAST DALLAS, TX 75244 ASSURE ALL CABLES SHIPPED TO THE VENDORS FACILITY INCLUDE A RETURN ADDRESS. ALL DEPOT STOCK SHALL BE PLACED ON CONDITION CODE "D" AND SHALL NOT BE ISSUED UNTIL THE DISCREPANT POWER CABLES HAVE BEEN REPLACED. E. DISPOSITION OF HAZARDOUS MATERIAL - N/A. 11. SPECIAL TOOLS, JIGS AND FIXTURES REQUIRED - N/A. 12. APPLICATION - A. CATEGORY OF MAINTENANCE - N/A B. TIME REQUIRED - N/A C. ESTIMATED COST IMPACT OF STOCK FUND ITEMS TO THE FIELD - N/A. D. TB/MWOS TO BE APPLIED PRIOR TO OR CONCURRENTLY WITH THIS INSPECTION - N/A. E. PUBLICATIONS WHICH REQUIRE CHANGE AS A RESULT OF THIS INSPECTION - THE NEW TM FOR THE TESTER, WHICH IS NOT PUBLISHED AS YET WILL REFLECT THE NEW THREE WIRE CABLE CONFIGURATION. 13. REFERENCES - NONE 14. RECORDING AND REPORTING REQUIREMENTS - A. REPORTING COMPLIANCE SUSPENSE DATE (AIRCRAFT) - N/A. B. TASK/INSPECTION REPORTING SUSPENSE DATE (AIRCRAFT) - N/A C. REPORTING COMPLIANCE SUSPENSE DATE (SPARES) - N/A. D. TASK/INSPECTION REPORTING SUSPENSE DATE (SPARES) - N/A. E. THE FOLLOWING FORMS ARE APPLICABLE AND ARE TO BE COMPLETED IN ACCORDANCE WITH DA PAM 738-751, 15 JUNE 92 - SF FORM 368, CATEGORY II QUALITY DEFICIENCY REPORT. 15. WEIGHT AND BALANCE - N/A. 16. POINTS OF CONTACT - A. TECHNICAL POINT OF CONTACT FOR THIS MESSAGE IS MS. VALERIE HALDIMAN, AMSAT-R-EIG, DSN 693-1675 OR COMMERCIAL 314/263- 1675. B. LOGISTICAL POINT OF CONTACT FOR THIS MESSAGE IS MR. JOHN DENNEY, AMSAT-W-AG, DSN 693-2828 OR COMMERCIAL 314/263-2828. C. SAFETY POINT OF CONTACT FOR THIS MESSAGE IS MR. HOWARD CHILTON, AMSAT-C-XS, DSN 693-2258 OR COMMERCIAL 314/263-2258. D. FOREIGN MILITARY SALES (FMS) RECIPIENTS REQUIRING CLARIFICATION OF ACTION ADVISED BY THIS MESSAGE SHOULD CONTACT MR. RON VAN REES, AMSAT-I-IOA, DSN 693-2626 OR COMMERCIAL 314/263- 2626. E. AFTER HOURS CONTACT ATCOM COMMAND OPERATIONS CENTER (COC) DSN 693-2066/7 OR COMMERCIAL 314/263-2066/7.